Перегляд за Автор "Lazurik, V.M."
Зараз показуємо 1 - 5 з 5
- Результатів на сторінці
- Налаштування сортування
Документ Dose field formation in thin films irradiated by electron beams: comparison of the Monte Carlo simulation with dosimetry(Харкiвський нацiональний унiверситет iм. В.Н. Каразiна, 2009) Kaluska, I.; Lazurik, V.T.; Lazurik, V.M.; Popov, G.F.; Rogov, Y.V.; Zimek, Z.The simulation of the absorbed dose distribution into thin films with different thickness inserted between flat boundaries of two homogeneous materials as well as the absorbed dose distribution near to boundaries of these materials irradiated with a scanned electron beam were fulfilled. Films inserted in multi-layer targets were parallel orientated with an incident electron beam (EB). The simulation was performed by the Monte Carlo (MC) method with utilization of the software ModePEB which was designed for predictions of a dose distribution in heterogeneous targets irradiated by EB with the electron energy range from 0.1 to 25 MeV. Comparison results of MC simulation with dosimetry for electron dose distribution formation in multi-layer targets with thin films is discussed. Проведено моделирование распределения поглощенной дозы в тонких пленках разной толщины, расположенных между плоскими границами двух гомогенных материалов, а также распределения поглощенной дозы вблизи границы этих материалов, облучаемых сканирующим пучком электронов. Пленки в многослойных мишенях были ориентированы параллельно падающему пучку электронов. Моделирование проводилось методом Монте Карло с использованием программы ModePEB, разработанной для предсказаний распределения дозы в гетерогенных мишенях, облучаемых пучком электронов с энергией от 0.1 до 25 МэВ. Обсуждается сравнение результатов Монте Карло моделирования с дозиметрией для формирования распределения дозы электронов в многослойных мишенях с тонкими пленками. Проведено моделювання розподілу поглиненої дози в тонких плівках різної товщини, розташованих між плоскими границями двох гомогенних матеріалів, а також розподіл поглиненої дози біля границі цих матеріалів, що опромінюються сканованим пучком електронів. Плівки у багатошарових мішенях були орієнтовані паралельно падаючому пучку електронів. Моделювання проводилось методом Монте Карло із використанням програми ModePEB, яку розроблено для передбачення розподілу дози в гетерогенних мішенях, що опромінюються пучком електронів з енергією від 0.1 до 25 МеВ. Обговорюються порівняння результатів Монте Карло моделювання із дозиметрією для формування розподілу дози електронів у багатошарових мішенях із тонкими плівками.Документ Dose mapping of a gamma industrial radiation facility using a practical and computational dosimetry(Харкiвський нацiональний унiверситет iм. В.Н. Каразiна, 2012) Boshnakova, N.; Lazurik, V.T.; Lazurik, V.M.; Popov, G.; Rogov, Yu.; Бошнакова, Н.; Лазурик, В.Т.; Лазурик, В.М.; Попов, Г.Ф.; Рогов, Ю.В.Comparison results for absorbed dose mapping of the Co60 industrial radiation facility BULGAMMA of Sopharma PLC, Bulgaria using a practical and computational dosimetry are presented in the paper. The gamma radiation facility is based on JS-8500 Co60 irradiator produced by MDS Nordian, Canada. The absorbed dose distributions of gamma rays in an irradiated product on JS-8500 Co60 irradiator have been calculated using the ModeGR Monte Carlo software. The software ModeGR was designed specially for simulation of the absorbed dose distribution within multi-layer packages irradiated with gamma ray from flat panoramic Co60 source rack using a Monte Carlo method. Absorbed dose measurements into containers filled with material using Ethanol Chlorobenzene chemical dosimeters were carried out to validate the software ModeGR. The comparison results show that software ModeGR can be used as a predictive tool for detailed dose mapping in gamma irradiated product. В работе рассматривается сравнение результатов картографирования поглощенной дозы гамма излучения Co60 на промышленном радиационном оборудовании БУЛГАММА, Софарма, София, Болгария с использованием практической и компьютерной дозиметрии. Гамма радиационное оборудование основано на излучателе JS-8500 Co60 производства фирмы MDS Nordian, Canada. Расчет распределение поглощенной дозы гамма излучения в облучаемой продукции на JS-8500 Co60 излучателе проводилось методом Монте Карло программой ModeGR. Программа ModeGR была специально разработана для моделирования распределение поглощенной дозы в многослойных мишенях, облучаемых гамма излучением на плоском панорамном излучателе Co60. Измерение поглощенной дозы гамма излучения в контейнерах, заполненных материалом, проводилось химическими дозиметрами Ethanol Chlorobenzene для валидации программы ModeGR. Результаты сравнения экспериментальных и расчетных данных показали, что программа ModeGR может использоваться как инструментарий для предсказания детальной карты поглощенной дозы в гамма облученной продукции. У роботі розглядається порівняння результатів картографування поглиненої дози гама випромінювання Co60 на промисловому радіаційному обладнанні БУЛГАММА, Софарма, Софія, Болгарія з використанням практичної й комп'ютерної дозиметрії. Гама радіаційне обладнання базується на випромінювачі JS-8500 Co60 виробництва фірми MDS Nordіan, Canada. Розрахунок розподілу поглиненої дози гама випромінювання в продукції, що опромінюється на JS-8500 Co60 випромінювачі, проводився методом Монте Карло програмою ModeGR. Програма ModeGR була спеціально розроблена для моделювання розподілу поглиненої дози в багатошарових мішенях, що опромінюються гама випромінюванням на плоскому панорамному випромінювачі Co60. Вимірювання поглиненої дози гама випромінювання в контейнерах, заповнених матеріалом, проводилося хімічними дозиметрами Ethanol Chlorobenzene для валідації програми ModeGR. Результати порівняння експериментальних і розрахункових даних показали, що програма ModeGR може використовуватися як інструментарій для прогнозування детальної карти поглиненої дози в гама опроміненої продукції.Документ Experimental benchmarking of software ModeStEB for simulation electron beam processing(V.N. Karasin Kharkiv National University, 2010) Lazurik, V.T.; Lazurik, V.M.; Popov, G.F.; Rogov, Y.V.; Kaluska, I.; Zimek, Z.Introduction success of radiation technologies into practice substantially depends on development of computational dosimetry which is based on accurate and validated programs, capable effectively calculate absorbed dose in processes of an irradiation. The simulation of the absorbed dose distributions into thin polyvinylchloride dosimetric films located in the stack of plates of a reference materials irradiated with a scanned electron beam was performed. Modeling of electron beam dose distributions in the multi-layer packages was accomplished using the Monte Carlo method in a three-dimensional geometrical model with utilization of the software ModeStEB. Results of benchmarking experiment for the software ModeStEB, which is used for simulation of industrial electron beam processing, are considered.Успех внедрения радиационных технологий в практику существенно зависит от развития компьютерной дозиметрии основанной на точных и валидированных программах, способных эффективно рассчитывать поглощенную дозу в процессах облучения. Проведено моделирование распределения поглощенной дозы в тонких поливинилхлоридных дозиметрических пленках, расположенных в пакете пластин из известных материалов, который облучался сканирующим пучком электронов с энергией 10 МэВ. Моделирование распределения поглощенной дозы пучка электронов в многослойном пакете проводилось методом Монте Карло в трехмерной геометрии с использованием программы ModeStEB. Обсуждаются результаты экспериментальной проверки программы ModeStEB, которая используется для моделирования промышленных электронно-лучевых технологий. Успіх впровадження радіаційних технологій у практику суттєво залежить від розвитку комп’ютерної дозиметрії, яка грунтується на точних та валідірованих програмах, здатних моделювати поглинену дозу в процесах опромінення. Проведено моделювання розподілу поглиненої дози в тонких полівінілхлоридних плівках, розташованих у пакеті пластин із відомих матеріалів, які опромінювались скануючим пучком електронів з енергією 10 МеВ. Моделювання розподілу поглиненої дози у багатошаровому пакеті проводилось методом Монте Карло у трьох-вимірній геометрії із використанням програми ModeStEB. Обговорюються результати експериментальної перевірки програми ModeStEB, яка використовується для моделювання промислових електронно-променевих технологій.Документ Integration of computation methods into radiation sterilization process(Харкiвський нацiональний унiверситет iм. В.Н. Каразiна, 2008) Lazurik, V.T.; Lazurik, V.M.; Popov, G.F.; Rogov, Y.V.; Zimek, Z.Authors have developed the computer technology for simulation of practical tasks in radiation sterilization process in accordance with Method 1, Standard ISO 11137 and IAEA Code of Practice. The technology was realized on the base of the RT-Office modules for modeling by Monte Carlo method of an absorbed dose in an irradiated heterogeneous targets with electron beam (EB), X-ray and gamma-ray and specialized software ModeSAL. The software ModeSAL was used for simulation and comparative analysis of a sterility assurance level (SAL) and a sterilizing dose for bioburden to achieve a required SAL in an irradiated product. The mathematical approach of the technology is based on the detailed and precise consideration of a self-consistent physical and geometrical models of calculation an EB, X-ray and gamma-ray dose maps in an irradiated product, a SAL, a sterilizing dose and the spatial and time uncertainties for dose provided to an irradiated product. The analysis of interrelations between parameters of EB radiation facility and values of a SAL and a sterilizing dose are considered. Разработана компьютерная технология для решения практических задач процесса радиационной стерилизации в соответствии со стандартом ISO 11137 и кодами практики МАГАТЭ. Технология реализована на основе модулей RT-Office и специализированного программного обеспечения ModeSAL. Модули RT-Office предназначены для расчета методом Монте-Карло поглощенной дозы в гетерогенных мишенях, облучаемых пучками электронов, тормозным или гамма излучением. Программное обеспечение ModeSAL использовалось для моделирования и сравнительного анализа уровня стерильности и стерилизационной дозы для микробной контаминации в облучаемом продукте. Математический подход технологии основан на детальном и корректном учете самосогласованных физических и геометрических моделей расчета поля дозы электронов, тормозного и гамма излучения, уровня стерильности и стерилизационной дозы а также пространственных и временных неоднородностей дозы в облучаемой мишени. Проводится анализ взаимосвязи между параметрами радиационного оборудования пучков электронов и величинами уровня стерильности и стерилизационной дозы.Документ Integration of computational methods in spectrometry of electron beams(Харкiвський нацiональний унiверситет iм. В.Н. Каразiна, 2012) Lazurik, V.T.; Lazurik, V.M.; Popov, G.F.; Rogov, Yu.V.; Sarukhanian, G.E.; Лазурик, В.Т.; Лазурик, В.М.; Попов, Г.Ф.; Рогов, Ю.В.; Саруханян, Г.Е.Investigations related with developments of computer simulation and computational methods for spectrometry of sources irradiation are actual for decision of wide class of scientific tasks into industrial radiation processing. Investigations of influence of electron beam spectrum characteristics on the spatial absorbed dose distributions formation into materials with various atomic numbers were performed. Simulation of spatial distributions of electrons absorbed dose in an irradiated targets was accomplished with the Monte Carlo method by the program ModeRTL. Analysis of numerical experiments results are discussed. Дослідження, спрямовані на розвиток засобів комп’ютерного моделювання і розрахункових методів для спектрометрії джерел радіаційного випромінювання, являються актуальними для рішення широкого класу задач в промислових радіаційних технологіях. Проведено дослідження впливу спектральних характеристик пучка електронів на формування розподілу поглиненої дози у матеріалах із різними атомними номерами. Моделювання просторового розподілу поглиненої дози електронів в опромінюваних мішенях проводилось методом Монте Карло із використанням програми ModeRTL. Обговорюються результати чисельних експериментів. Исследования, направленные на развитие средств компьютерного моделирования и вычислительных методов для спектрометрии источников излучения, являются актуальными для решения широкого класса научных задач в промышленных радиационных технологиях. Проведено исследование влияния спектральных характеристик пучка электронов на формирование распределений поглощенной дозы в материалах с различными атомными номерами. Моделирование пространственных распределений поглощенной дозы электронов в облучаемых мишенях проводилось методом Монте Карло с использованием программы ModeRTL. Обсуждаются результаты численных экспериментов.